Search results for " Doppler"

showing 10 items of 373 documents

Guiding and splitting Lamb waves in coupled-resonator elastic waveguides

2018

Abstract We investigate experimentally Lamb wave propagation in coupled-resonator elastic waveguides (CREWs) formed by a chain of cavities in a two-dimensional phononic crystal slab with cross holes. Wide complete bandgaps, extending from 53 to 88 kHz, are first measured in a finite phononic crystal slab sample. A straight waveguide and a wave splitting circuit with 90° bends are then designed, fabricated and measured. Elastic Lamb waves are excited by a piezoelectric patch attached to one side of the phononic slab and detected using a scanning vibrometer. Strongly confined guiding and splitting at waveguide junctions are clearly observed for several guided waves. Numerical simulations are …

010302 applied physicsMaterials sciencebusiness.industryPhysics::Optics02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesPiezoelectricitylaw.inventionCrystalResonatorLamb wavesOpticslaw0103 physical sciencesDispersion (optics)Ceramics and CompositesSlab0210 nano-technologybusinessLaser Doppler vibrometerWaveguideCivil and Structural EngineeringComposite Structures
researchProduct

Surface sediment dynamics along the shore of Hammamet Gulf (Tunisia, southern Mediterranean)

2016

International audience; In the summer of 2015 the authors analysed grain size and surface sediment composition through high spatial resolution from samples taken at 53 stations along the Hammamet coast (southern Mediterranean Sea). The Acoustic Doppler Current Profiler deployed in this study showed that the surface current flows toward the north-east, parallel to the coast at a maximum speed along the main axis of about 5.9 cm s−1. Near the bottom the current flows toward the north-west at a maximum speed of 2.2 cm s−1. The tide plays a relatively small role in water circulation in Hammamet Gulf. Spatial distribution of particle size, along with speed and current direction analysis, furnish…

010504 meteorology & atmospheric sciences010501 environmental sciencesSpatial distribution01 natural sciences[ SDE ] Environmental SciencesMediterranean seaAcoustic Doppler current profilerCurrents14. Life underwaterGeomorphology0105 earth and related environmental sciencesEarth-Surface ProcessesShoregeographyMineralsgeography.geographical_feature_categorySedimentGeologyParticle sizeSediment dynamicsHammamet GulfSwellCurrent (stream)Oceanography13. Climate action[SDE]Environmental SciencesSubmarine pipelineGeology
researchProduct

Validation of HF radar sea surface currents in the Malta-Sicily Channel

2019

Abstract A network of High-Frequency radar (HFR) stations runs operationally in the Malta-Sicily Channel (MSC), Central Mediterranean Sea, providing sea surface current maps with high temporal (1 h) and spatial (3 × 3 km) resolutions since August 2012. Comparisons with surface drifter data and near-surface Acoustic Doppler Current Profiler (ADCP) observations, as well as radar site-to-site baseline analyses, provide quantitative assessments of HFR velocities accuracy. Twenty-two drifters were deployed within the HFR domain of coverage between December 2012 and October 2013. Additionally, six ADCP vertical current profiles were collected at selected positions during a dedicated field survey.…

010504 meteorology & atmospheric sciencesFrequency band0208 environmental biotechnologySoil Science02 engineering and technologySurface current01 natural scienceslaw.inventionAcoustic Doppler current profilerlawCurrent meter measurementHfr cellComputers in Earth SciencesRadar0105 earth and related environmental sciencesRemote sensingHF radarSettore ICAR/02 - Costruzioni Idrauliche E Marittime E IdrologiaData qualityGeology020801 environmental engineeringCurrent (stream)DrifterDrifter measurementSettore ICAR/06 - Topografia E CartografiaGeologyCommunication channelInterpolationRemote Sensing of Environment
researchProduct

The predictive power of transcranial sonography in movement disorders: a longitudinal cohort study.

2018

Transcranial sonography (TCS) is a noninvasive, easily performed, and commonly available neuroimaging technique useful for the study of brain parenchyma in movement disorders. This tool has been increasingly used in the diagnosis of Parkinson’s disease and atypical parkinsonism. The aim of the study was to evaluate the applicability of this technique as supportive tool in the early diagnosis of movement disorders. We performed TCS on 315 individuals which were diagnosed as healthy controls or affected by idiopathic Parkinson’s disease, monogenetic subtypes of Parkinson’s disease, atypical parkinsonism, and Dementia with Lewy bodies. Five TCS diagnostic patterns were defined on the basis of …

0301 basic medicineMalemedicine.medical_specialtyMovement disordersNeurologyUltrasonography Doppler TranscranialConcordanceDementia with Lewy bodiesDermatologyDiseaseCohort Studies03 medical and health sciences0302 clinical medicineNeuroimagingPredictive Value of TestsInternal medicineSubstantia nigramedicineLenticular nucleiHumansNeuroradiologyAgedMovement DisordersDementia with Lewy bodiesbusiness.industryfungiGeneral MedicineMiddle Agedmedicine.diseasePsychiatry and Mental health030104 developmental biologyAtypical parkinsonismIdiopathic Parkinson’s diseaseTranscranial sonographySettore MED/26 - NeurologiaFemaleNeurology (clinical)Neurosurgerymedicine.symptombusiness030217 neurology & neurosurgeryNeurological sciences : official journal of the Italian Neurological Society and of the Italian Society of Clinical Neurophysiology
researchProduct

Two-dimensional and three-dimensional sonography of conjoined twins.

2002

Purpose The aim of this study was to evaluate and compare the diagnostic capabilities of 2-dimensional (2D) and 3-dimensional (3D) sonography for the study of conjoined twins. Methods Four pregnant women with an initial 2D sonographic diagnosis of conjoined twins were examined with color Doppler sonography, 3D multiplanar sonography, and orthogonal plane imaging and 3D surface rendering. Results All 4 cases of conjoined twins were initially diagnosed with either transvaginal or transabdominal 2D sonography. 3D sonography afforded more realistic views and demonstrated more clearly the linking areas and surface anomalies, but 2D and color Doppler sonography provided more definitive and specif…

3d sonographyAdultMalemedicine.medical_specialty3 dimensional ultrasonographybusiness.industryOrthogonal planeUltrasoundInfant NewbornColor dopplermedicine.diseaseSurgeryPregnancyConjoined twinsmedicineHumansRadiology Nuclear Medicine and imagingSurface renderingFemaleRadiologyUltrasonographyUltrasonography Doppler ColorbusinessTwins ConjoinedUltrasonographyJournal of clinical ultrasound : JCU
researchProduct

Accuracy of doppler echocardiography in measuring right-heart pressure in patients with pulmonary hypertension

2010

The assessment of pulmonary pressure is of great clinical importance not only for diagnostic purposes, but also for prognosis in patients with pulmonary arterial hypertension. The present study was undertaken on a consecutive basis with a group of patients who had had a previous diagnosis of pulmonary hypertension based on echocardiography, and were referred to our institute. The aim of this study was to determine how accurate Doppler echocardiography is in measuring right-heart pressures.

Accuracy doppler echocardiography pulmonary hypertension
researchProduct

Glycoprotein and ganglioside changes in human trophoblasts after exposure to pulsed doppler ultrasound

1995

Changes in glycoprotein and ganglioside composition in human trophoblasts (eighth week of gestation) after in vitro exposure to pulsed Doppler ultrasound (pulse duration 1.22 microseconds; repetition frequency 11.1 kHz; center frequency 4 MHz; ISPPA = 175.5 W/cm2; ISPTA = 0.59 W/cm2) were investigated. Evacuated trophoblasts were divided in two halves and insonated for 10 min on top of a 6-cm layer of 5% gelatin in 50-mL tubes (Falcon) at 37 degrees C. One half of each trophoblast was sham insonated and served as an internal control. After insonation trophoblasts were maintained at 37 degrees C for 24 h. Glycoproteins were detected using alpha-D-mannose specific lectins from Galanthus nival…

Acoustics and UltrasonicsImmunoblottingBiophysicsMannoseG(M2) Gangliosidechemistry.chemical_compoundGangliosidesLectinsmedicineG(M3) GangliosideHumansRadiology Nuclear Medicine and imagingGlycoproteinschemistry.chemical_classificationMembrane GlycoproteinsGangliosideGalanthusRadiological and Ultrasound TechnologybiologyChemistryTrophoblastLectinMolecular biologyN-Acetylneuraminic AcidTrophoblastsMolecular WeightMembrane glycoproteinsglycoproteins; gangliosides; lectins; pulsed doppler ultrasoundmedicine.anatomical_structureUltrasonography Doppler PulsedG(M2) GangliosideImmunologySialic Acidsbiology.proteinElectrophoresis Polyacrylamide GelChromatography Thin LayerPlant LectinsGlycoproteinMannoseN-Acetylneuraminic acid
researchProduct

Ultrasonographic Detection of Vascularity of Focal Breast Lesions: Microvascular Imaging Versus Conventional Color and Power Doppler Imaging.

2021

To compare microvascular flow imaging (MVFI) to conventional Color-Doppler (CDI) and Power-Doppler (PDI) imaging in the detection of vascularity of Focal Breast Lesions (FBLs). A total of 180 solid FBLs (size: 3.5–45.2 mm) detected in 180 women (age: 21–87 years) were evaluated by means of CDI, PDI, and MVFI. Two blinded reviewers categorized lesion vascularity in absent or present, and vascularity pattern as (a) internal; (b) vessels in rim; (c) combined. The presence of a “penetrating vessel” was assessed separately. Differences in vascularization patterns (chi2 test) and intra- and inter-observer agreement (Fleiss method) were calculated. ROC analysis was performed to assess performance…

AdultBreast Neoplasms01 natural sciencesSensitivity and Specificity030218 nuclear medicine & medical imagingDiagnosis Differential03 medical and health sciencessymbols.namesakePower dopplerYoung Adult0302 clinical medicineVascularity0103 physical sciencesmedicineHumansRadiology Nuclear Medicine and imagingBreastUltrasonography Doppler Color010301 acousticsAgedAged 80 and overRadiological and Ultrasound Technologybusiness.industryUltrasonography DopplerMiddle AgedROC CurvesymbolsFemalebreast Doppler imaging microvessels ultrasonographymedicine.symptomUltrasonographyNuclear medicinebusinessDoppler effectMicrovascular flowUltrasonic imaging
researchProduct

Carotid artery intima-media thickness: normal and percentile values in the Italian population (camp study)

2011

AIMS: Carotid intima-media thickness (IMT) is one of the best non-invasive parameters for evaluating previous vascular lesions and could be used to identify a preclinical stage of the atherosclerotic process. The aim of our research was to develop an epidemiological study of the normal mean values of IMT of the common carotid artery, adjusted for age and sex, in the Italian population. METHODS AND RESULTS: In this multicenter study, a total of 1017 patients (596 males, mean age: 58.5 + 13.2 years) were enrolled at four different Italian centers. Inclusion criteria were the absence of cardiovascular risk factors or presence of not more than one. Patients underwent two-dimensional echo-color …

AdultCarotid Artery DiseasesMaleAgingmedicine.medical_specialtyPercentileCarotid Artery CommonEpidemiologyCarotid arteriesYoung AdultCarotid artery intima-mediaAge DistributionSex FactorsReference Valuesmedicine.arteryEpidemiologymedicineHumanscardiovascular diseasesCommon carotid arterySex DistributionUltrasonography Doppler ColorYoung adultAgedAged 80 and overbusiness.industryAge FactorsMiddle AgedSettore MED/11 - Malattie Dell'Apparato CardiovascolareItalian populationItalyIntima-media thicknessMulticenter studycardiovascular systemFemaleRadiologyTunica IntimaTunica MediaCardiology and Cardiovascular MedicinebusinessEuropean Journal of Cardiovascular Prevention & Rehabilitation
researchProduct

Pre- and intraoperative methods of controlling cerebral circulation in giant aneurysm surgery.

1995

The surgical treatment of giant aneurysms usually requires temporary clipping of the aneurysmatic vessel. In planning the surgical approach and in applying temporary clips, the surgeon must consider collateral circulations. The functional integrity of the collateral vessels frequently decides the patient's outcome. In 8 patients with internal carotid artery giant aneurysm, measurements of blood flow velocities in the ipsilateral middle cerebral artery were performed preoperatively with transcranial Doppler ultrasound (TCD) during manual occlusion of the carotid artery at the neck. Three different perfusion patterns were established, and each collateral capacity was rated as insufficient, te…

AdultCarotid Artery DiseasesMalemedicine.medical_specialtyUltrasonography Doppler TranscranialCollateral CirculationBasal GangliaBrain IschemiaCerebral circulationAneurysmmedicine.arteryMonitoring IntraoperativeOcclusionMedicineHumansDominance CerebralAgedCerebral Cortexbusiness.industryBrainIntracranial AneurysmGeneral MedicineBlood flowMiddle AgedCollateral circulationmedicine.diseaseTranscranial DopplerSurgeryRegional Blood FlowMiddle cerebral arterycardiovascular systemSurgeryFemaleNeurology (clinical)RadiologyInternal carotid arterybusinessBlood Flow VelocityCarotid Artery InternalNeurosurgical review
researchProduct